Recommendation: 2026004-02

back to recommendations listing

Ref # 2026004-02
Status Open / In progress
Occurrence Signal Passed at Danger, Killarney Junction, 8th February 2025
Occurrence Date 08 February 2025

Basis for Recommendation

After the SPAD, the Mainline CTC Signalman was unable to contact Train A309 via a REC as they did not press the PTT; this was likely to have been influenced by the type of training given and the low frequency of performing the task. Whilst the IÉ-IM recommendation partially addresses this in training, the RAIU considers that repeated opportunities to carry out the task is likely to achieve a reliable performance.

Recommendation

IÉ-IM to provide simulation facilities that permit the simulation of RECs and incorporate the use of these in the routine competency assessment of signalmen.